THE-1105 1 Installation Guide
Installation Guide
Humidity Transmitter w/ Temperature Sensor
THE-1105
Mounting
Handy Box Mounting (Recommended)
1. Install,butDO NOT TIGHTEN,theHMO-
5024/5026/5030/5031mountingplatetoahandy
boxusingthetwo6-32screws(included).
2. Adjustandlevelthebackplate(inthevertical
orhorizontalplane)usingthesloedmounting
holesandtightenthetwomountingscrews.
3. RemovetheTHE-1105’scoverbyturningthetwo
setscrews(ontheside)clockwise(inward)usinga
1/16"hexwrenchuntilthecoverclearsthebase.
4. Pullallthewiresorwirecablethroughthe
backplate’sdecorativetrimplateopening
(includedwithHMO-5024/5026/5030/5031)and
throughthecableaccessholeintheTHE-1105.
5. Makesurethatthehumiditysensorisinthe
lowerrightcorner(verticalinstallation)orlower
lecorner(horizontalinstallation)ofthebase.
6. Connectthewires(seeWiringsection).
7. MounttheTHE-1105tothebackplatewiththe
two6-20x2"self-tappingscrews(included).
8. Reinstallthecoverandlockitbyturningthe
setscrewscounter-clockwise(outward).
Hollow Wall Mounting
Mountingonahollowwallupto5/8"thickcanbe
donewiththeHMO-5023orHMO-5001.Tomount
withanHMO-5023:
1. Usingthetemplate,cuta1-1/2"x2-11/16"
openinginthedrywall.
2. RemovetheTHE-1105’scoverbyturningthetwo
setscrews(ontheside)clockwise(inward)usinga
1/16"hexwrenchuntilthecoverclearsthebase.
3. LooselymounttheHMO-5023brackettothe
thermostat(coverremoved)usingthetwo6-32x
2"screws.
4. Pullthewiresthroughthewireaccessholesinthe
HMO-5023andtheTHE-1105.
5. Makesurethatthehumiditysensorisinthe
lowerrightcorner(verticalinstallation)orlower
lecorner(horizontalinstallation)ofthebase.
6. Connectthewires(seeWiringsection).
5. Insertbracketdiagonally,throughthewall
opening,centerandtightenscrews.
8. Reinstallthecoverandlockitbyturningthe
setscrewscounter-clockwise(outward).
HMO-50xx Mounting Plate
(Shown in horizontal installation)
HMO-5023 Drywall Mounting Kit
Mounting 1
Location 1
Handy Box Mounting (Recommended) 1
Hollow Wall Mounting 1
Wiring 2
Maintenance 2
More Information 2
Important Notices 2
Location
Installthesensoronaninsidewallwhereitcansense
theaverageroomtemperature/humidityandbe
awayfromdirectsunlight,heatsources,windows,
airvents,andaircirculationobstructions(curtains,
furniture,etc.).
CAUTION
Check that the
thermistor leads are
not bent and that the
thermistor bead is
upright (perpendicular
to the board) BEFORE
reinstalling the cover.
Przeglądanie stron 0
1 2

Podsumowanie treści

Strona 1 - Installation Guide

THE-1105 1 Installation GuideInstallation GuideHumidity Transmitter w/ Temperature SensorTHE-1105 MountingHandy Box Mounting (Recommended)1. Insta

Strona 2 - More Information

THE-1105 2 Installation Guide© 2013 KMC Controls, Inc. 870-019-01GKMC Controls, Inc.19476IndustrialDriveNewParis,IN46553574.831.5250www.kmcc

Komentarze do niniejszej Instrukcji

Brak uwag